Optimize power generation output curve Reduce wind and light abandonment and increase the share of renewable energy in power generation
Optimize the power generation output curve, reduce wind and light abandonment, and increase the proportion of renewable energy in power generation
CTP is used to design the battery pack, and the single module is integrated into the integrated module structure, and directly assembled on the battery pack tray, reducing the module transfer and lifting, and improving the assembly efficiency.
System fire protection adopts cluster fire protection design to achieve cluster detection and improve real-time fire detection. The use of perfluorohexanone fire extinguishing agent, strong fire extinguishing, low toxicity, environmental protection, etc.
The system adopts distributed temperature control design and adopts the form of one-cluster thermal management to effectively improve the consistency of the operating temperature of the battery system, so that the temperature difference of the system is less than 8℃ and the operating stability of the system is improved.
entry | PotisBank-A5.0-1500 | PotisBank-A5.2-1500 |
|
---|---|---|---|
Number of battery packs | 150.05kWh/m² | 156.05kWh/m² | |
Battery cluster configuration |
1P400S(
25Battery pack)
|
1P416S(
26Battery pack)
|
|
Nominal voltage | 1280V | 1331.2V | |
Voltage range |
Auxiliary power supply1040~1460V(
cell: 2.8V~3.65V)
|
1081.6~1518.4V(
cell: 2.8V~3.65V)
|
|
Rated energy |
5.0176 MWh
|
5.218304MWh
|
|
weight |
58Tons
|
60Tons
|
|
Cell type |
LFP
|
||
Battery pack configuration |
1P16S
|
||
Number of battery clusters |
14
|
||
Charge and discharge ratio |
0.5P
|
||
Short-circuit current |
98kA
|
||
Communication mode |
Ethernet/RS485/CAN
|
||
Communication protocol |
Modbus TCP / Modbus RTU / CAN 2.0
|
||
Design standard |
GB/T 36276-2018, UN38.3, IEC62619,NFPA69, NFPA70, NFPA855,NFPA68
|
||
Auxiliary equipment power supply |
380V/480V
|
||
Auxiliary power |
40kW
|
||
Standby power supply |
2hour
|
||
Operating ambient temperature |
-20℃ to 55℃(-4°to 131°F)
|
||
Working altitude |
<2000m ( 2000m~4000m, Downpower operation)
|
||
Thermal management |
air conditioner
|
||
Size (length * width * height) |
13716*2438*2896mm
|
||
Protection class |
IP20
|
||
color |
RAL9010
|
||
Seismic load strength |
Zone 4
|
||
Noise level |
70 dB(A)
|
||
Fire protection system |
Heptafluoropropane or perfluorohexanone
|
||
Spot stop |
Yes
|
||
Remote emergency stop |
Yes
|
||
Fire detection |
container
|
||
Thermal diffusion technique |
Yes
|
||
FCL delivery (built-in battery) |
Yes
|
||
Battery protection class |
IP54
|
||
Full power operating range |
SOC5%~100%@25℃
|
||
Maximum number of cycles |
4 Times per day
|