122cc太阳集成游戏(中国)官方网站-BinG百科
Optimize power generation output curve
Reduce wind and light abandonment and increase the share of renewable energy in power generation
Location: Home Product Center
Optimize the power generation output curve, reduce wind and light abandonment, and increase the proportion of renewable energy in power generation
PotisBank-A air-cooled storage systems provide world-leading clean energy technologies to improve power quality, energy efficiency and environmental performance.BESS matches a variety of electrical systems to improve operational performance and reliability, not only enabling smoother integration of renewable energy sources, but also helping to balance power supply and demand.
Super performance
Rapid assembly

CTP is used to design the battery pack, and the single module is integrated into the integrated module structure, and directly assembled on the battery pack tray, reducing the module transfer and lifting, and improving the assembly efficiency.

Safety and environmental protection

System fire protection adopts cluster fire protection design to achieve cluster detection and improve real-time fire detection. The use of perfluorohexanone fire extinguishing agent, strong fire extinguishing, low toxicity, environmental protection, etc.

Stable and efficient

The system adopts distributed temperature control design and adopts the form of one-cluster thermal management to effectively improve the consistency of the operating temperature of the battery system, so that the temperature difference of the system is less than 8℃ and the operating stability of the system is improved.

Product parameters
entry PotisBank-A5.0-1500 PotisBank-A5.2-1500

 

Number of battery packs 150.05kWh/m² 156.05kWh/m²  
Battery cluster configuration
1P400S(
25Battery pack)
1P416S(
26Battery pack)
 
Nominal voltage 1280V 1331.2V  
Voltage range
Auxiliary power supply1040~1460V
cell: 2.8V~3.65V)
1081.6~1518.4V
cell: 2.8V~3.65V)
 
Rated energy
5.0176 MWh
5.218304MWh
 
weight
58Tons
60Tons
 
Cell type
LFP
 
Battery pack configuration
1P16S
 
Number of battery clusters
14
 
Charge and discharge ratio
0.5P
 
Short-circuit current
98kA
 
Communication mode
Ethernet/RS485/CAN
 
Communication protocol
Modbus TCP / Modbus RTU / CAN 2.0
 
Design standard
GB/T 36276-2018, UN38.3, IEC62619,NFPA69, NFPA70, NFPA855,NFPA68
 
Auxiliary equipment power supply
380V/480V
 
Auxiliary power
40kW
 
Standby power supply
2hour
 
Operating ambient temperature
-20℃ to 55℃(-4°to 131°F)
 
Working altitude
<2000m ( 2000m~4000m, Downpower operation)
 
Thermal management
air conditioner
 
Size (length * width * height)
13716*2438*2896mm
 
Protection class
IP20
 
color
RAL9010
 
Seismic load strength
Zone 4
 
Noise level
70 dB(A)
 
Fire protection system
Heptafluoropropane or perfluorohexanone
 
Spot stop
Yes
 
Remote emergency stop
Yes
 
Fire detection
container
 
Thermal diffusion technique
Yes
 
FCL delivery (built-in battery)
Yes
 
Battery protection class
IP54
 
Full power operating range
SOC5%~100%@25℃
 
Maximum number of cycles
4 Times per day
 

 

 

 

 

Other products
Consultation and advice